Operation Manual
Handling alarms
This chapter provides information on how to handle alarms.
Some of the features described in this chapter can be deactivated for your user group.
Notice!
A map displayed in an Alarm Image pane is optimized for display and contains only the initial
view of the basic .dwf file.
Accepting an alarm
Main window > > tab
or
Main window >
> tab
You can accept a single alarm or multiple alarms for clearing or starting a workflow.
To accept an alarm:
1. Select the desired alarm entry and click .
2. For returning to the Image window, click .
When an alarm is accepted, several things happen simultaneously:
– The alarm is removed from Alarm Lists of all other users.
– If not already displayed, an Alarm Image window replaces the Live Image window on the
monitor that has been enabled for alarms.
– The alarm content (live video, instant playback video, or site maps) is shown in a row of
Alarm Image panes in the Alarm Image window.
– If there is a workflow associated with the alarm, the workflow button
is enabled.
You can now clear the alarm or start a workflow. If the alarm has been configured to
"force workflow", then you must complete the workflow before you can clear the alarm.
To display an alarm camera on an analog monitor:
4 Drag the camera image from its Alarm Image pane to an analog monitor group.
Adding comments to an alarm
Main window > > tab > Select the desired alarm >
or
Main window > > tab > Select the desired alarm >
You can only comment an alarm after you have accepted it.
10
10.1
10.2
50 en | Handling alarms Bosch Video Management System
2013.07 | V1 | Operator Client Operator's Manual Bosch Sicherheitssysteme GmbH