Installation Sheet

Table Of Contents
20
3.
Remove the nozzle D and replace it with an
appropriate nozzle for the new type of gas.
Small burner/large burner
Dual-flame burner
4.
Place the burner cup B onto the burner C and place
the burner cover A onto the burner cup B.
5.
Refit the grates.
Setting the minimum gas flow
1.
Remove the control knob and knob ring.
2.
Turn the inner setting screw clockwise gently until it
bottoms out.
Note: In case of conversion from propane gas to
natural gas, turn out all bypass nozzles for 1/2 turn.
Small burner/large burner
Dual-flame burner:
3.
Replace the control knobs.
4.
Light each burner individually and check for flame
stability on low setting.
5.
If required, loosen the setting screw to increase the
gas flow.
6.
Ensure that the flame does not go out when the gas
flow is quickly changed between maximum and
minimum, and vice versa. The optimum setting is
achieved when the height of the small flame is
approx. 1/8" (3to 4 mm).
7.
Refit the control knob and knob ring for the gas
burner.
8.
Repeat steps 2to 8until all of the gas burners have
been set.
9.
Connect the appliance to the power supply.
'
$
%
&