Operation Manual

Table Of Contents
Figure 5.3: Exploded View of Composite Cable Connections
Camera
Cable
Connector
Pin
Signal Name Description Cable Wire
Color
1 Washer Drive Rtn Auxiliary Connection Grey
2 Tamper Sw Rtn Auxiliary Connection Brown
3 Washer Drive Wash Signal Orange
4 Tamper Sw Alarm Communications Black
5 Video Return Video Signal Ground Coax
Screen
6 Video Output Video Output to Control Room Coax Core
7 Full Duplex Tx B+ Telemetry I/O to RS-422/485 Violet
8 Full Duplex Tx A- Telemetry I/O to RS-422/485 Blue
9 0v Ground Shield
10 Full Duplex Rx A-
Half Duplex Tx/Rx A
Telemetry I/O to RS-422/485 Yellow
11 Full Duplex Rx B+
Half Duplex Tx/Rx B
Telemetry I/O to RS-422/485 White
12 Power Input 2 Low Voltage Power Input Green
13 Power Input 1 Low Voltage Power Input Red
Earth Link on PCB
The printed circuit board (PCB) of each MIC PSU (IR and non-IR) has one Earth Link option,
near terminal block HD1, to allow the PSU to be set up for different earthing schemes:
If there is a separate connection between video screen and earth, the Earth Link should
be broken. This usually occurs on copper-connected systems where all of the copper
video coaxes are taken back to the control room to be connected to a central earth point.
If fiber optics or other indirect connections are used to get data and video to and from
the control room, then the Earth Link should be left intact, as long as it is the only
camera-end earth reference point.
5.4
16 en | Install the MIC (standard) PSU MIC612 Thermal Camera
2016.03 | 2.2 | F.01U.249.416 Operation Manual Bosch Security Systems