Signal Pin
Number
Washer
Pump
1
Washer
Pump
2
!
Warning!
The washer pump terminal is rated only to 24 VAC or VDC maximum voltage and is not
suitable for Mains-operated pumps.
4 Test the washer by pressing the red button marked SW1 PUMP ON on the PCB.
LED 3 illuminates in response to telemetry commands from the control room to turn on
the washer. Note that the software in the camera prevents the washer from running more
than 10 seconds continuously to prevent emptying the washer bottle.
28. After wiring is complete, connect the power supply to the power source.
29. Verify that the following LEDs are lit:
LED Description
LED 2 18 VAC power on to camera
LED 4 Power on for optional heater
LED 3 18 VAC power on camera
LED 5 Power on for optional heater
26 en | Install the MIC (standard) PSU MIC612 Thermal Camera
2016.03 | 2.2 | F.01U.249.416 Operation Manual Bosch Security Systems