Operation Manual
Table Of Contents
- Title Page
- Table of Contents
- Safety
- Unpacking
- Product Description
- Electrical Connections
- Install the MIC (standard) PSU
- MIC PSU Overview
- About the MIC Shielded Composite Cable
- Composite Cable Color-coding
- Earth Link on PCB
- Fuse Ratings
- Alarm Inputs
- Layout of MIC Power Supply Units (PSUs)
- Installation Warnings and Prerequisites
- Installation Instructions (Power Supply)
- Commissioning the Camera with Heater Option Fitted
- Simultaneous IP and Analog Video/Control ("Hybrid" Operation)
- Fit the Sunshield (MIC612)
- Getting Started
- Controlling the Camera
- On-Screen Display (OSD) Menus (Bosch Protocol)
- On-Screen Display (OSD) Menus (Pelco Protocol)
- Operation of the Thermal Camera
- Common User Commands
- Advanced Features
- Maintenance and Troubleshooting
- Technical data
- Appendices
- Back Page
Signal Pin
Number
Washer
Pump
1
Washer
Pump
2
!
Warning!
The washer pump terminal is rated only to 24 VAC or VDC maximum voltage and is not
suitable for Mains-operated pumps.
4 Test the washer by pressing the red button marked SW1 PUMP ON on the PCB.
LED 3 illuminates in response to telemetry commands from the control room to turn on
the washer. Note that the software in the camera prevents the washer from running more
than 10 seconds continuously to prevent emptying the washer bottle.
28. After wiring is complete, connect the power supply to the power source.
29. Verify that the following LEDs are lit:
LED Description
LED 2 18 VAC power on to camera
LED 4 Power on for optional heater
LED 3 18 VAC power on camera
LED 5 Power on for optional heater
26 en | Install the MIC (standard) PSU MIC612 Thermal Camera
2016.03 | 2.2 | F.01U.249.416 Operation Manual Bosch Security Systems