Preset Command Description
94-PRESET Initiates a Preset Tour.
95-PRESET Enables or disables Limit Stops in the Setup Menu for AutoScan.
Invokes the Pelco main Setup Menu when pressed for 2 seconds.
96-PRESET Stops a scan.
97-PRESET Initiates FastAddress (Pelco Random Scan).
98-PRESET Toggles the Synch. Mode between Line Lock and Internal (Pelco
Frame Scan). This command is available only for two (2) minutes after
the power is applied and then reverts to normal preset functionality.
99-PRESET Starts an AutoScan.
Notice!
Some Pelco controllers do not support all of the preset command numbers. Refer to the
documentation of the specific Pelco controller for supported preset commands.