Operation Manual
Table Of Contents
- Title Page
- Table of Contents
- Safety
- Unpacking
- Product Description
- Electrical Connections
- Install the MIC (standard) PSU
- MIC PSU Overview
- About the MIC Shielded Composite Cable
- Composite Cable Color-coding
- Earth Link on PCB
- Fuse Ratings
- Alarm Inputs
- Layout of MIC Power Supply Units (PSUs)
- Installation Warnings and Prerequisites
- Installation Instructions (Power Supply)
- Commissioning the Camera with Heater Option Fitted
- Simultaneous IP and Analog Video/Control ("Hybrid" Operation)
- Fit the Sunshield (MIC612)
- Getting Started
- Controlling the Camera
- On-Screen Display (OSD) Menus (Bosch Protocol)
- On-Screen Display (OSD) Menus (Pelco Protocol)
- Operation of the Thermal Camera
- Common User Commands
- Advanced Features
- Maintenance and Troubleshooting
- Technical data
- Appendices
- Back Page
Inactivity
Selects the mode to which the camera reverts after the period of inactivity set in the inactivity
period. Options:
Option Description
Scene 1 Returns to Preset 1.
Prev Aux Returns to previous activity, such as Aux commands 1, 2, 7, 8, 50,
or 52.
OFF (Default setting) Remains on the current scene indefinitely.
Inact. Period
Sets the time period of inactivity before the above action occurs.
Sliding scale: – (3 sec. to 10 min.) +. Default setting: 2 min.
Autopivot
Automatically rotates the camera 180º when following a subject traveling directly beneath the
camera. Options: ON (default setting), OFF.
Orientation
Selects mounting options. Options:
Option
Description
NORMAL (Default setting) The camera is straight, upright; the software does
not rotate the view.
INVERTED The sofware rotates the video 180º automatically.
Freeze Frame On Preposition
Holds a preposition video frame while moving to another preposition. Options: ON (default
setting), OFF.
Tilt Up Limit...
Sets the upper tilt limit of the camera. Use the joystick to move to a scene.
Azimuth Zero...
Sets the zero degree pan position. Use the joystick to move to a scene that you want to set as
the zero degree pan position and as the North compass heading. For more details, refer to
Azimuth, Elevation, and Compass Directions, page 80.