Operation Manual

Table Of Contents
Communication Setup Menu
The Communication Setup Menu contains baud rate and Bilinx control settings.
Communication Setup
Exit...
* AutoBaud: ON
* Baud Rate: 9600
Bilinx
Restore Defaults
* = Factory Setting
Focus / Iris: Select
AutoBaud
Turns on AutoBaud detection, which detects and adjusts the camera protocol and baud rate to
match that of the controller. Options: ON (default setting), OFF. ON automatically accepts
baud rates from 2400 to 57600.
Note: If stepping from 2400 to 57600 baud, you must first set the Baud Rate to 19200 for
AutoBaud to detect the higher baud rate.
Baud Rate
Manually sets the baud rate when AutoBaud is set to OFF. Options are 2400, 4800, 9600
(default setting), 19200, 38400, and 57600.
Bilinx
Activates Bilinx control communication. (Only available when not connected to a Bilinx data
interface unit.) Options: ON (default setting), OFF.
9.6
54 en | On-Screen Display (OSD) Menus (Bosch Protocol) MIC612 Thermal Camera
2016.03 | 2.2 | F.01U.249.416 Operation Manual Bosch Security Systems