Operation Manual

Table Of Contents
Option Description
Off (Default setting) No test pattern is available.
Ascending ramp A test pattern appears in the analog and digital data channels, to
allow you verify the output of the digital data channel.
The figure below is a horizontal slice of the complete image; the
pattern repeats 19 times in the complete image.
When displayed on an analog video monitor, and if the AGC mode
is not set to the default value, the pattern may appear differently
than shown here.
Slice of complete image (320 x 256 or 640 × 512)
1: (0,0) = 0
2: (639,0) = 639
3: (25,408) (320 models)/(383,25) (640 models) = 16383
4: (25,409) (320 models)/(384,25) (604 models) = 0
Vertical
.
Color bars
Notice!
Before activating the test pattern, turn off the correction terms and set the AGC Mode to
Outdoor. This mode will not persist over a power cycle.
Total Time On
Displays the total time that the video has been on.
Alarm Status Submenu
This menu displays the status of the alarm inputs and outputs.
The Alarm Status submenu appears differently depending upon the Multi-Alarm setting.
Alarm Status
Exit...
Alarm Input 1 Open
Alarm Input 2 Open
Alarm Input 3 Open
Alarm Input 4 Open
Alarm Input 5 Open
64 en | On-Screen Display (OSD) Menus (Bosch Protocol) MIC612 Thermal Camera
2016.03 | 2.2 | F.01U.249.416 Operation Manual Bosch Security Systems