Operation Manual
Table Of Contents
- Title Page
- Table of Contents
- Safety
- Unpacking
- Product Description
- Electrical Connections
- Install the MIC (standard) PSU
- MIC PSU Overview
- About the MIC Shielded Composite Cable
- Composite Cable Color-coding
- Earth Link on PCB
- Fuse Ratings
- Alarm Inputs
- Layout of MIC Power Supply Units (PSUs)
- Installation Warnings and Prerequisites
- Installation Instructions (Power Supply)
- Commissioning the Camera with Heater Option Fitted
- Simultaneous IP and Analog Video/Control ("Hybrid" Operation)
- Fit the Sunshield (MIC612)
- Getting Started
- Controlling the Camera
- On-Screen Display (OSD) Menus (Bosch Protocol)
- On-Screen Display (OSD) Menus (Pelco Protocol)
- Operation of the Thermal Camera
- Common User Commands
- Advanced Features
- Maintenance and Troubleshooting
- Technical data
- Appendices
- Back Page
Using the Wiper/Washer (Bosch Protocol)
The "predefined position" for the wash/wipe function is preset 62. The installer must define
preset 62 (preferably where the washer nozzle is located and can direct washer fluid towards
the camera window) before using the wiper/washer function.
To activate the washer/wiper function, press ON-105-ENTER, and then confirm this
sequence:
1. The wiper moves to a predefined position.
2. The washer turns on for five seconds. Simultaneously, the wiper turns on and wipes five
times.
3. The washer turns off. The wiper continues wiping for five more wipes as the camera
returns to its initial PTZ position (and to inactive mode if applicable).
4. The wiper turns off.
To activate intermittent wipe:
Press ON-103-ENTER. The wiper wipes twice, then returns to parked position, and then turns
off 15 seconds later. This sequence will continue for up to 5 minutes or until an OFF-103-
ENTER command is sent.
To activate continuous wipe:
Press ON-102-ENTER. The wiper wipes continuously for up to 5 minutes, or until another
OFF-102-ENTER command is sent (if the command is sent before the 5 minutes elapse). The
wiper then turns off automatically.
To activate the wiper to wipe five (5) times:
Press ON-104-ENTER. The wiper wipes five (5) times, or until an OFF-104-ENTER command is
sent (if the command is sent before the wiper wipes five (5) times), then returns to parked
position and turns off.
12.3
MIC612 Thermal Camera Common User Commands | en 77
Bosch Security Systems Operation Manual 2016.03 | 2.2 | F.01U.249.416