Operation Manual

Table Of Contents
Setting the Azimuth Zero Point
The MIC550 or the MIC612 uses the Azimuth Zero point, usually set to magnetic North, as the
zero degree pan position and as the North compass heading. The MIC550 or the MIC612 then
displays the azimuth reading and the compass heading based on the number of degrees from
the Azimuth Zero point.
!
Caution!
Bosch recommends that only the installer calibrate the Azimuth Zero point. A recalibration to
the Azimuth Zero point may cause inaccurate compass headings.
To set the Azimuth Zero point:
1. Determine the North compass heading, then move the camera to that position.
2. Press OFF-90-ENTER to turn off the command lock (if active).
3. Press ON-94-ENTER to set the Azimuth Zero point.
Displaying Azimuth, Elevation, and Compass Headings
You can display only the azimuth/elevation readings or only the compass reading, or you can
display both readings at the same time. The MIC550 or the MIC612 displays the azimuth/
elevation readings and the compass heading in the following way:
180 / –45 S
where:
180 is the Azimuth or the pan location in degrees.
–45 is the Elevation or the tilt location in degrees.
S is the compass direction (cardinal or intercardinal).
1. Press ON-95-ENTER to display the azimuth/elevation reading.
2. Press ON-96-ENTER to display the compass heading.
3. Press OFF-95-ENTER to hide the azimuth/elevation reading.
4. Press OFF-96-ENTER to hide the compass heading.
13.5.1
13.5.2
MIC612 Thermal Camera Advanced Features | en 81
Bosch Security Systems Operation Manual 2016.03 | 2.2 | F.01U.249.416