Installation Guide

backed parquet.
Do not use in areas subject to hydrostatic head.
Do not use MultiGrip™ as a moisture vapor membrane beneath
solid or bamboo flooring.
This membrane is designed to reduce moisture vapor emissions
that originate/emanate from below the membrane only.
This membrane does NOT reduce/affect issues originating
from the sides, ends, or top of flooring (ie. puddles, water, leaks,
hydrostatic-head, etc.).
This membrane does NOT eliminate all possible moisture
related or install related issues (i.e. improper acclimation of
flooring, jobsite temperature/relative humidity, etc.).
This membrane is designed to prevent excessive variance of
moisture between the top, middle, and bottom of flooring that
originates from the substrate.
PACKAGING
Available in the following sizes:
5 gallon (18.9 L) pails (36 pails/pallet)
4 gallon (15.1 L) pails (36 pails/pallet)
2 gallon (7.5 L) pails (64 pails/pallet)
Certain sizes not available in all locations.
CAUTION
COMBUSTIBLE. HARMFUL IF SWALLOWED OR INHALED.
CONTAINS POTENTIAL SENSITIZER. MAY CAUSE ALLERGIC
SKIN OR LUNG REACTION. MAY IRRITATE EYES, SKIN AND
RESPIRATORY TRACT. Do not breathe fumes. Do not get in
eyes, on skin or on clothing. Do not swallow. Use only in a well-
ventilated area or wear mask. Keep away from flames or sparks.
Wash thoroughly after handling. Store container in a cool
(50° and 100°F /10° and 38°C), dry area with lid tightly sealed. Do
not reuse container.
WARNING
This product contains a chemical(s) known to the State of California
to cause cancer and/or birth defects or other reproductive harm.
SEE MATERIAL SAFETY DATA SHEET.
LIMITED WARRANTY
Limited Warranty found at www.bostik-us.com or call
800.726.7845. TO THE MAXIMUM EXTENT ALLOWED BY
LAW, BOSTIK DISCLAIMS ALL OTHER EXPRESS OR IMPLIED
WARRANTIES, INCLUDING WITHOUT LIMITATION WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. UNLESS OTHERWISE STATED IN THE LIMITED
WARRANTY, THE SOLE REMEDY FOR BREACH OF WARRANTY IS
REPLACEMENT OF THE PRODUCT OR REFUND OF THE BUYER’S
PURCHASE PRICE. BOSTIK DISCLAIMS ANY LIABILITY FOR DIRECT,
INCIDENTAL, CONSEQUENTIAL, OR SPECIAL DAMAGES TO THE
MAXIMUM EXTENT ALLOWED BY LAW. DISCLAIMERS OF IMPLIED
WARRANTIES MAY NOT BE APPLICABLE TO CERTAIN CLASSES OF
BUYERS AND SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO
THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. It is the buyer’s
obligation to test the suitability of the product for an intended use
prior to using it. The Limited Warranty extends only to the original
purchaser and is not transferable or assignable. Any claim for a
defective product must be filed within 30 days of discovery of a
problem, and must be submitted with written proof of purchase.
CHEMICAL & PHYSICAL PROPERTIES
Use
Environments
Residential Yes
Offices/Light Commercial Yes
Heavy Commercial Yes
Hospital No
Exterior No
Wet Areas No
Substrates
Concrete Yes
Plywood Yes
OSB Yes
Well-Bonded Vinyl Yes
Terrazzo Yes
Ceramic Tile Yes
Cement Backer Board Yes
Gypsum Underlayments* Yes
Cement Patch/Underlayment Yes
Flooring
Types
Solid Hardwood Yes
Engineered Hardwood Yes
Bamboo Yes
Cork Yes
Parquet Yes
Plywood Yes
Ceramic Tile, Marble,
Stone Inlays
*2
Yes
Cured
Physical
Properties
Cure Time
*3
Light foot traffic
Normal foot traffic
6 to 8 hours
8 to 12 hours
Water Vapor Permeability
*4
< 0.9
Concrete Moisture Vapor
Limits for subfloor moisture
vapor protection:
ASTM 1869
Calcium Chloride Method
≤ 6 lbs/
1000 sq ft /24 hrs
ASTM 2170
Relative Humidity Test
≤ 80% RH
Elongation >180%
Service Temperature
-40°F to 150°F
(-40°C to 66°C)
Uncured
Physical
Properties
Ease of Troweling Easy
Odor Mild
Open/Working Time
*5
180 minutes
Color White
Density (lbs/gallon) 13.7
Percentage of Water
*6
0%
Percentage of Adhesive
Coverage Required:
For Moisture
Protection
For
Bond
Engineered 100% >80%
Solid 100% >95%
Application Temperature
50°F to 100°F
(10°C to 38°C)
Chemical
Properties
Chemistry Type 1-Part Urethane
Adhesive Type Moisture Cure
VOC Compliant
(as calculated per SCAQMD Rule 1168)
Yes (<85 g/L)
Flash Point, closed cup ≥142°F (61°C)
*
Dry, above grade
*2
Residential or light commercial only
*3
Humidity affects cure to a greater degree than temperature; the higher the
humidity, the faster the cure. Under normal conditions, light foot traffic is
acceptable after 6 to 8 hours; normal traffic after 12-16 hours.
*4
Per ASTM E-96 Standard Test Methods for Water Vapor Transmission of materials.
Ratings are g/m2-24 hour-mmHG.
*5
Please refer to the Open/Working Time Chart.
*6
Per ASTM E203-01 Standard Test Method for water using Volumetric Karl Fischer
Titration Method. Results rounded to the nearest tenth. Test Method has error