Specifications

2-7
OPERATION
POLARITY
NOTE: Often polarity is mistakenly called phase. As phase indicates
any angle between two channels from 0 to 360 degrees, the correct term
of polarity is preferred to indicate the 180° phase change, or inversion,
available in the 2010 Preamplifier.
To activate a polarity change only in one channel, start by pressing
either the L POLARITY or R POLARITY pushbuttons. “POL NORMAL”
will show in the right display. If you want to change the polarity in
the left channel, press the L POLARITY pushbutton while “POL...” is
displayed. “POL L INVRTD” will show in the right display and the
output polarity of the left channel main outputs will be inverted.
Similarly, you may change the polarity only in the right channel, by
pressing R POLARITY while “POL...” is displayed. “POL R INVRTD”
will show in the right display and the output polarity of the right
channel main outputs will be inverted.