User guide

Electrical Supply 230v., 1 Ph., 50Hz.
IMPORTANT
The Electrical Installation of this appliance must be performed by a suitably qualified electrical
engineer/installer.
A
ll wiring to supply and all system components external to boiler must comply with the latest edition of
BS7671:1992 formerly IEE Wiring Regulations.
This appliance must be effectively earthed and connection to the supply must be through a double pole
isolating switch fused 5 amp.
The isolating switch must have all pole contact separations at least 3mm
BOULTER BUDERUS CAMRAY 5 PA
GE 7
3:5 DIMENSIONS
* Conventional Flue Size
Output A B C D E F G H J Flue
K*
L Weight
Empty
Water
Content
Filled
Weight
Model kW Btu/h x
1000
mm mm mm mm mm mm mm mm mm ø
ins
ø
ins
Kgs Litres Kgs
40/65 11.7/19 40/65 860 596 446 130 121 540 55 65 92 4" 1
BSP
112 17.5 130
65/90 19/26.4 65/95 860 596 446 130 121 540 55 65 92 4" 1
BSP
114 21.0 135
95/130 27.8/38.1 100/140 1000 704 508 149 139 640 66 100 112 5"
1
1
/
4
BSP
166 29.8 196
Pa
g
e 13 of 67
14/04/2005file://D:\PL47000\PL47000.htm