acidic due to the fuel characteristics and it is advisable not to install the flue in any position where the
condensation could cause damage to paint surfaces etc.
2. The Terminal index plate should be sealed to the external wall using silicon sealant or other impervious
material to prevent water ingress.
3. Ensure that the outlet of the Terminal points downward (TOP upper-most and Boulter correct way up).
4. Ensure that the boiler to offtake gasket is fitted (foil face upwards) and the clamp is made with four nuts and
washers securely fixed.
5. Ensure that the ‘Sealing Rings’ are fitted in the correct groove. Use a mild detergent as a lubricant to ease
assembly.
6. The Flue is telescopic and no cutting of the flue pipes is necessary.
7. 500mm and 1000mm flue extension kits are available. Do not exceed the maximum flue lengths stated in
this manual.
8. The flexible air duct is an integral part of the appliance and must be used on all balanced flue kits. Ensure
that it is not damaged and that either end is connected via the jubilee clip provided to ensure correct boiler
operation.