10. Take High Level elbow fit larger O Ring seal to short arm, lubricate with a mild detergent and ensure flue
exhaust seal is fitted to the inner duct undamaged and in the correct orientation.
11. Ensuring there is no debris in the wall place longer arm through drilled hole and slide into second
extension being careful not to scratch metal work.
The high level elbow must be slightly sloped downwards.
12. Using the drill provided drill 6 holes as indicated on the drawing and secure with the self tapping screws
supplied.
13. FROM OUTSIDE
Remove the outer terminal four screws and put terminal to one side.
14. Taking outer air duct ensure Seal is fitted and in good condition.
15. Check wall cavity for debris and remove if necessary. Slide the outer air duct into the inner air duct until
home.
16. Using the four holes on the external wall plate as a guide drill four fixing holes into the external wall to suit
those supplied.
17. Replace the outer air duct and pushing firmly home screw into position (4 screws). Weather seal all
edges.
18. Taking the terminal end, keeping it square to the external flange push home over the internal flue exhaust
pipe until the four holes on the flange align.
NB. Ensure that TOP is on the upper-most surface of the terminal and BOULTER is upright.
19. Secure the terminal to the flange using the four screws. 20. Fit an approved terminal guard if in accessible
position. Available from Boulter Buderus.
21. INSIDE
Use the clips supplied to fix the air duct to the burner spigot and vertical flue offtake spigot Continue with the
rest of the installation.
Fig. 6:3b High Level Horizontal Flue Assembly