User guide

IF NOT THIS MAY DAMAGE THE PUMP.
Clear oil filters and de-sludge the tank if necessary.
TWO PIPE OIL SYSTEMS
Is a spring-loaded non-return oil valve fitted in the suction line? (or a 3K Oil Deaerator).
Does the return oil line terminate in the take at the same level as the suction outlet?
Has an anti-syphon cut been made in the return oil line (inside the tank)?
BOILER
Is the boiler standing on a level incombustible hearth?
Are the thermostat phials inserted in their pockets?
Are the baffles and bottom insulation (where applicable) correctly located?
Is the boiler set for the fuel being supplied?
Has the system and boiler been filled with water and inhibitor as required?
Is the boiler flueway inspection cover screwed down sufficiently firmly to form a seal?
BOULTER BUDERUS CAMRAY 5
PAGE 41
7:4 BOULTER BUDERUS RECOMMENDED COMMISSIONING CHECK LIST - SHEET 2 OF 2
CASING PANELS
Have grommets been fitted to relevant oil supply entry points (knockouts)?
Does electrical cabling pass through a grommet to prevent chaffing?
BURNER
Is the oil pump by-pass screw fitted, if applicable?
Remove the burner. Is the correct nozzle fitted?
NOTE:- Burner operating instructions can conflict because they are intended for general guidance. Since the
burner has been specifically matched to the particular boiler, the information in the Boiler manual takes
precedence.
FLUE AND CHIMNEY
Pa