1:4 BOILER CONTROL PANEL
Boiler Control Panel (see fig 1)
1. Boiler Control Thermostat Switch/Mains On Switch.
2. Boiler Overheat/Limit Thermostat Reset Button.
3. ‘Lockout’ Indicator- RED. }These will not be lit until activated
4. Mains Indicator- ORANGE }These will not be lit until activated
5. Limit Indicator - RED. }These will not be lit until activated
6. Burner on Indication - ORANGE.
1:5 OPERATING INSTRUCTIONS
1:5.1 BOILER CONTROL THERMOSTAT
The Boiler Control Thermostat is also the ON/OFF switch for the Boiler. The ‘MAINS ON’ orange neon
indicator on the Control Panel is lit when external power is being supplied to the boiler. To Switch the
Boiler off, turn the Thermostat to the ‘OFF’ position and isolate at the mains isolating switch or external control
until the orange neon indicator is no longer lit.
The Boiler Control Thermostat also controls the water temperature within the Boiler. The recommended
Control Thermostat settings are as follows:
WINTER HEATING & HOT WATER SEE FIG 1
SUMMER HOT WATER ONLY SEE FIG 1
The Boiler Control Thermostat automatically switches the Burner ON and OFF to maintain the selected
temperature. The Burner is lit by an automatic ignition system and therefore there is no pilot flame.
The Boiler should not be operated below 60°C as this will cause corrosion which will reduce the life of the
Boiler (Summer position).
1:5.2 BOILER OVERHEAT/LIMIT THERMOSTAT
The Boiler is fitted with a safety overheat/limit thermostat. This will interrupt the power supply to the Boiler and
shut it down completely in the unlikely event of overheating.
Should this occur, the red limit indicator on the Control Panel will be illuminated. Wait for the Boiler to cool,
and then reset the thermostat by pressing the limit thermostat reset button located under the Control Panel -
see fig 1.
If this problem still persists, turn off the Boiler and consult your installer.
1:5.3 BURNER RUNNING INDICATOR
(Camray5 Kitchen Model only)
The boiler is quieter than most oil fired boilers and to indicate the burner is running a indicator neon is
included. If the indicator is lit and the burner is not firing contact your installer.