POR TABL E AIR CON DITI ONE R Model: MPN1-08CR MPN1-10CR Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner. Before operating this product, please read the instructions carefully and save this manual for future use.
CONTENTS SAFETY PRECAUTIONS Safety rules ........................................................................................................................................2 Electrical information ..........................................................................................................................2 IDENTIFICATION OF PARTS Accessories ........................................................................................................................................
SAFETY PRECAUTIONS Safety rules To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. ! Always do this Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Unplug immediately.
IDENTIFICATION OF PARTS Accessories O F Check all the accessories are included in the package and please refer to the installation instructions for their usage. Suggested tools for window kit installation 1. Screwdriver(medium size Phillips) 2. Tape measure or ruler 3. Knife or scissors 4.
IDENTIFICATION OF PARTS NAMES OF PARTS Before Using This Air Conditioner, be Sure To Check The Back Of The Unit To Make Sure That The Lower Drain Plug Is Security In Place . See Fig.2 12 FRONT VIEW 1 1 Operation Panel 2 Horizontal Louvers 3 Caster 4 Carrying Handle (both sides) 5 Upper Air Filter (Behind the grille) 6 Air Outlet 7 Power cord outlet 8 Air intake 9 Drain Outlet 2 4 3 Fig.
AIR CONDITIONER FEATURES ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin, thoroughly familiarize yourself with the control panel and remote controller and all functions, then follow the symbol for the functions you desire. The unit can be controlled by the unit control panel alone or with the remote controller . OPERATION PANEL OF THE AIR CONDITIONER 6 4 4 5 SWING HI AUTO COOL F C MED TIMER ON DRY SLEEP MODE FAN TIMER OFF FAN 7 8 1 2 LOW 3 Fig.
AIR CONDITIONER FEATURES 3 FAN button HI F C MED TIMER ON SLEEP TIMER OFF 4 UP( ) and DOWN( Press to increase F FAN LOW ) button Press to decrease C TIMER ON SLEEP TIMER OFF 5 LED Display F NOTE: Used to adjust (increasing/decreasing) temperature settings(1 C/2 F increments) in a range of 17 C(62 F) to 30 C(88 F) or the TIMER setting in a range of 0~24hrs.. If you want the display to read the actual room temperature, see " To Operate on Dry Only" or " To Operate on Fan Only" section.
AIR CONDITIONER FEATURES SWING button SWING AUTO COOL F C TIMER ON DRY MODE TIMER OFF FAN MODE select button SWING AUTO COOL F C TIMER ON DRY MODE FAN TIMER OFF Use the SWING button to adjust the UP/DOWN airflow direction (Perform this function while the unit is in operation). 1. Press the SWING button, the swing feature is activated. o 2. Each press will change the swing angle for 6 . Keep pressing the button to move the horizontal louver to the desired position.
AIR CONDITIONER FEATURES TIMER button SWING AUTO COOL F TIMER ON DRY MODE FAN TIMER OFF C NOTE: When the unit is on, first press the Timer button, the indicator light above word TIMER OFF illuminates. It indicates the Auto Stop program is initiated. When the unit is off, first press the Timer button, the indicator light above word TIMER ON illuminates. It indicates the Auto Start program is initiated. Press or hold the UP arrow or DOWN arrow to change the Auto time by 0.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1 COOL OPERATION - Press the "MODE" button several times until the "COOL" indicator light comes on. - Press the UP and DOWN buttons or to select your desired room temperature. The temperature can be set within a range of 17OC-30OC/62OF-88OF. - Press the "FAN " button to choose the fan speed. 2 DRY OPERATION (DEHUMIDIFY) - Press the "MODE" button until the "DRY" indicator light comes on.
OPERATING INSTRUCTIONS 6 WATER DRAINAGE: During dehumidifying mode: - Remove the drain plug from the back of the unit,attach a section of drain hose (included with this unit) to the hole. Place the open end of the hose directly over the drain area in your basement floor or in a water container (see Fig.4 & 5). - You can also install the drain connector (5/8" (1.58cm) universal female mender) with 3/4" (1.9cm) hose (locally purchased by consumer) for garden hose use.
INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Location 30c m (0 .9 8 ft ) 30 cm (0 .9 8f t) Fig.7 The air conditioner should be placed on a firm foundation to minimize noise and vibration. For safe and secure positioning, place the unit on a smooth, level floor strong enough to support the unit. The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects.
INSTALLATION INSTRUCTIONS Installation in double-hung sash windows Foam seal A (adhesive type) 1. Cut the foam seal(adhesive type) to the proper length and attach it to the window stool. Fig.10 Fig.10 Window kit 2. Attach the window slider kit to the window stool. Adjust the length of the window slider kit according to the width of window, shorten the adjustable window kit if the width of window is less than 27 inches. Open the window sash and place the window slider kit on the window stool. Fig.
INSTALLATION INSTRUCTIONS Installation in a sliding sash windows Foam seal A (adhesive type) Fig.14 Window kit 1. Cut the foam seal(adhesive type) to the proper length and attach it to the window frame. See Fig.14. 2. Attach the window slider kit to the window stool. Adjust the length of the window slider kit according to the width of window, shorten the adjustable window kit if the width of window is less than 27 inches. Open the window sash and place the window slider kit on the window stool.
INSTALLATION INSTRUCTIONS Exhaust hose installation: Flat mouth Fig.18 Pu sh The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. COOL mode Install FAN or DEHUMIDIFY mode Remove 1. Install the window Exhaust adaptor (flat mouth) onto the exhaust hose as shown in Fig.18. Refer to the previous pages for window kit installation. in Hook Fig.19 2. Place the Exhaust hose over against the air outlet opening hook(See Fig.19) and flat the other end(See Fig.
CARE AND MAINTENANCE CARE AND MAINTENANCE Air filter (slide out) Fig.22 IMPORTANT: 1) Be sure to unplug the unit before cleaning or servicing. 2) Do not use gasoline, thinner or other chemicals to clean the unit. 3) Do not wash the unit directly under a tap or using a hose. It may cause electrical danger. 4) If the power cord is damaged, it should be repaired by manufacturer or its agent. 1. Air filter Remove the screw and take the air inlet grille down Fig.
TROUBLESHOOTING TIPS TROUBLE SHOOTING TROUBLES POSSIBLE CAUSES SUGGEST REMEDIES 1. Unit does not - P1 appears in the display window Drain the water in the bottom tray. Start when Pressing on/off Button - Room temperature is lower than the set temperature.(Cooling mode) - The windows or doors in the room are not closed. 2. Not cool enough - There are heat sources inside the blocked. doors are closed. Remove the heat sources if possible. Connect the duct and make sure it can function properly.
REMOTE CONTROLLER ILLUSTRATION Handling the remote controller Location of the remote controller. 8m T TE SE TO AU OL CO Y DR Use the remote controller within a distance of 8 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep.
REMOTE CONTROLLER ILLUSTRATION Remote Controller Specifications Model R51I13/BG(C)E ¡Á2) Rated Voltage 3.0V(Dry batteries R03/LR03 Lowest Voltage of CPU Emitting Signal 2.0V Signal Receiving Range 8m (when using 3.0 voltage, it Gets 11m) Environment -5 C~ 60 C( -41OF~140OF ) ¡£ ¡£ NOTE: Temperature setting display: Fahrenheit scale( F), R51I13/BG(C)E Performance Feature 1. Operating Mode: AUTO, COOL, DRY, and FAN. 2. Timer Setting Function in 24 hours. 3.
REMOTE CONTROLLER ILLUSTRATION Function buttons continued 8 TIMER ON Button Press this button to activate the Auto-on time setting. Each press will increase the time setting in 30 minutes increments, up to 10 hours, then at 1 hour increments up to 24 hours. To cancel the Auto-on time setting, just press the button until the time setting is 0.0. SET TEMPERATURE( F) FAN HIGH MED LOW AUTO COOL DRY 9 ECONOMY(SLEEP) Button Select this function during the sleeping time.
REMOTE CONTROLLER ILLUSTRATION How to use the buttons Auto operation SET TEMPERATURE( F) FAN HIGH MED LOW AUTO COOL DRY TEMP 2 3 MODE ON/OFF FAN SPEED 1 SWING ECONOMY RESET LOCK TIMER ON NOTE 1. In the AUTO mode, the air conditioner can logically choose the mode of Cooling, Fan, and Dehumidifying by sensing the difference between the actual ambient room temperature and the set temperature on the remote controller. 2. In the AUTO mode, you can not switch the fan speed.
REMOTE CONTROLLER ILLUSTRATION Swing operation Use the SWING button to adjust the Up/Down airflow direction. 1. When press the button once and quickly, the air flow direction setting feature of the louver is activated. The moving angle of the louver is 6o for each press. Keep pressing the button to move the louver to the desired position. 2. If keep pressing the SWING button without releasing for 2 more seconds, the auto swing feature of the louver is activated.
REMOTE CONTROLLER ILLUSTRATION To set the Auto-off time. SET TEMPERATURE( F) FAN HIGH MED LOW AUTO COOL DRY TIMER OFF TEMP ON/OFF FAN SPEED MODE SWING ECONOMY TIMER ON RESET LOCK TIMER OFF 1 LED DISPLAY 1. Press the TIMER OFF button. The remote controller shows TIMER OFF, the last Auto-off setting time and the signal "h" will be shown on the LCD display area. Now it is ready to reset the Auto-off time to START the operation. 2. Push the TIMER OFF button again to set desired Auto-off time.
REMOTE CONTROLLER ILLUSTRATION COMBINED TIMER (Setting both ON and OFF timers simultaneously) ¡ú h TIMER ON OFF Start Stop On Set 2 hours later after setting 10 hours later after setting ¡ú h Start Set Stop 2 hours later after setting Example: To stop the air conditioner 2 hours after setting and start it again 10 hours after setting. 1. Press the TIMER OFF button. 2. Press the TIMER OFF button again to display 2.0h on the TIMER OFF display. 3. Press the TIMER ON button. 4.