Installation / Operation Instruction Manual

15
GENERAL OPERATION
Before closing the switch to allow electric current to flow to the water heater,
make certain that the water heater is full of water and that the cold water inlet
valve is open. Complete failure of the heating elements will result if they are
not totally immersed in water at all times. When the switch is closed, the
operation of this electric water heater is automatic. The temperature control
knob located on the side on the control box is factory preset to 120°F (49°C).
Care must be taken whenever using hot water to avoid scalding injury.
Certain appliances require high temperature hot water (such as dishwashers
and automatic clothes washers).
TO FILL THE WATER HEATER
1. Close the water heater drain valve by turning the knob clockwise.
2. Open the cold water supply shut-off valve.
3. Open several hot water faucets to allow air to escape from the system.
4. When a steady stream of water flows from the faucets, the water heater
is filled. Close the faucets and check for water leaks at the water heater
drain valve, combination temperature and pressure relief valve and the
hot and cold water connections.
5. Reconnect power supply to water heater.
TO DRAIN THE WATER HEATER
Should it become necessary to completely drain the water heater, make sure
you follow the steps below:
1. Disconnect the power supply to the water heater. Consult the plumbing
professional or electric company in your area for service.
2. Close the cold water supply shut-off valve.
3. Open the drain valve on the water heater by turning the knob counter-
clockwise. The drain valve has threads on the end that will allow
connection of a standard hose coupling.
4. Open a hot water faucet to allow air to enter the system.
To refill the water heater, refer to “TO FILL THE WATER HEATER.
Thermostat Adjustment
To adjust the water temperature, locate the temperature control dial on the
right side of the control box. To increase the water temperature, rotate the
temperature control dial clockwise. To decrease the water temperature,
rotate the temperature control dial counterclockwise (see Figure 5). The
thermostat(s) or temperature control dial has been factory preset to
approximately 120°F (49°C).
CAUTION
Scalding may occur within five (5) seconds at a temperature setting of
140°F (60°C).