Installation / Operation Instruction Manual

6
Water Connections
Note: Before proceeding with the installation, close the main water
supply valve.
After shutting the main water supply valve, open a faucet to relieve the water
line pressure in order to prevent water from leaking out of the pipes while
making the water connections to the water heater. After the pressure has
been relieved, close the faucet. The cold water inlet line connects to the inlet
nipple at the base of the water heater. The hot water outlet line connects to
the nipple on top of the water heater. The fittings at the cold water inlet and
hot water outlet are dielectric waterway fittings with tapered male threads.
Make the proper plumbing connections between the water heater and the
plumbing system in the structure. Install a manual shut-off valve in the cold
water supply line.
This water heater may be provided with an optional pressure and
temperature gauge. See Figure 1 for proper installation.
If this water heater is installed in a closed water supply system, such as one
having a back-flow preventer in the cold water supply, provisions must be
made to control thermal expansion. DO NOT operate this water heater in a
closed system without a provision for controlling thermal expansion. Contact
your water supplier or local plumbing inspector regarding how thermal
expansion can be controlled.
After installation of the water lines, open the main water supply valve and fill
the water heater. While the water heater is filling, open several hot water
faucets to allow air to escape from the water system. When a steady stream
of water flows through the faucets, close the faucets and inspect all water
connections for possible leaks. NEVER OPERATE THE WATER HEATER
WITHOUT FIRST BEING CERTAIN IT IS COMPLETELY FILLED WITH
WATER.
CAUTION
If sweat fittings are to be used, DO NOT apply heat to the nipples on top
of the water heater. Sweat the tubing to the adapter before fitting the
adapter to the water connections. It is imperative that heat is not applied
to the nipples containing a plastic liner.
IMPORTANT
FAILURE TO INSTALL AND MAINTAIN A NEW, LISTED
TEMPERATURE-PRESSURE RELIEF VALVE WILL RELEASE THE
MANUFACTURER FROM ANY CLAIM WHICH MIGHT RESULT FROM
EXCESSIVE TEMPERATURE AND PRESSURES.