Troubleshoot

The indicator light illuminates but water is not heated or the
water temperature is too low:
STEP ONE:
The water flow is too high. Reduce the water flow using the faucet.
With experimentation, an increase in temperature should be observed.
Make sure the aerator supplied with the heater is attached to the faucet;
these are integral for proper performance of the unit. If the special aerator is
not included, call Technical Service at 1-800-334-3393 and one will be
shipped to you. BE CAREFUL, THE WATER EXITING THE FAUCET
IS HOT. SCALD INJURY CAN OCCUR FROM THE HOT WATER.
STEP TWO:
Make sure the unit is connected to the voltage supply specified on the U.L.
rating label located on the front cover of the unit.
STEP THREE:
Proceed to page five and follow STEP FOUR.
6