Installation / Operation Instruction Manual

1) The unit should be mounted as close to the point of use as possible.
2) This unit must only be mounted in the vertical position with the water
fittings at the bottom of the unit. Mounting other than in the vertical position
WILL cause element burn out.
3) The cold water inlet is on the right hand side and the hot water outlet is
on the left hand side. Under NO circumstances can these be reversed.
4) Leave a minimum of 8 ABOVE the unit for easy replacement of the
element.
5) The heater should be fixed to the wall using the four mounting holes at
each corner of the backplate.
NOTE: The heater should be installed below the level of all hot water
outlets serviced by this unit.
NOTE: PRESSURE RELIEF DEVICE
This unit is not required by UL to have a Pressure and Temperature
safety relief valve (PTRV). Consult local codes to find out if one is required
in your area.
If local codes require the use of temperature and pressure relief valve one
should be installed on the outlet hot water pipe before the outlet ball valve.
MOUNTING THE UNIT