Step 5: When the desired setpoint is reached on the water heater display, press the “Set” button to confirm the new
setpoint. “Setpoint” stops flashing in the water heater display.
SELECT SET
Status
°F
idle
setpoint
Operational
To Display and Change Temperature Format (°F/°C):
To Change Temperature Format in Display from °F to °C or °C to °F:
Step 1: While in “Service Mode”, press “Selectbutton until “°FC” is shown in the upper right po rtion of the water heater
display.
SELECT SET
Status
idle
Operational
°F °F/
Step 2: Press “Set” button to change temperature format. “°F/°C” symbol will fl ash in the water heater display.
SELECT SET
Status
idle
Operational
°F °F/
17