Service Manual

PV SERVICE PROCEDURE VI
Gas Control Testing and Replacement
PV Series
28
Gas Control Disassembly/Reassembly (cont.)
Step 8. Disconnect temperature sensor from control board.
Step 9. To reassemble gas control, follow the previous steps in reverse order. Once gas
control is reassembled, burner assembly is reinstalled, and the gas supply line is
reconnected, resume water supply to water heater. Be sure tank is full of water
before relighting.
Step 10. To resume operation, follow the instructions located on the lighting instruction label
or the lighting instructions located in the installation and operation manual.
CAUTION
Use care not to bend or damage valve body pins
when removing or installing gas control cover.
28