Service Manual

Specifications
PV Series
9
Vent Tables
Venting Specifications for:
RG1PV55H
RG2PV75H
LG1PV55H
LG2PV75H
3" Diameter (7.6 cm) Vent Connector Lengths
Terminating
# of
Elbows
Maximum Straight
Length ft. (m)
Minimum Straight
Length ft. (m)
Through the Wall
1
45 (13.7)
2 (.6)
Through the Wall
2
40 (12.2)
2 (.6)
Through the Wall
3
35 (10.7)
2 (.6)
Through the Wall
4
30 (9.1)
2 (.6)
Through the Roof
0
50 (15.2)
7 (2.1)
Through the Roof
1
45 (13.7)
7 (2.1)
Through the Roof
2
40 (12.2)
7 (2.1)
Through the Roof
3
35 (10.7)
7 (2.1)
4" Diameter (7.6 cm) Vent Connector Lengths
Terminating
# of
Elbows
Maximum
Straight
Length ft. (m)
Minimum
Straight
Length ft. (m)
Through the Wall
1
175 (53.3)
10 (3.1)
Through the Wall
2
170 (51.8)
10 (3.1)
Through the Wall
3
165 (50.3)
10 (3.1)
Through the Wall
4
160 (48.8)
10 (3.1)
Through the Wall
5
155 (47.2)
10 (3.1)
Through the Roof
0
180 (54.9)
15 (4.6)
Through the Roof
1
175 (53.3)
15 (4.6)
Through the Roof
2
170 (51.8)
15 (4.6)
Through the Roof
3
165 (50.3)
15 (4.6)
Through the Roof
4
160 (48.8)
15 (4.6)
9