Specifications

12
Installation (Venting) continued-
TABLE 2-VENT CONNECTOR LENGTHS FOR 4” (10.1 cm) DIAMETER PVC
Terminating # of 90° Elbows
(excluding vent
terminal)
Maximum
Length
Minimum
Length
Through the Wall 1 70 ft (21.5 m) 2 ft (.6 m)
Through the Wall 2 65 ft (20 m) 3 ft (.9 m)
Through the Wall 3 60 ft (18.5 m) 5 ft (1.5 m)
Through the Wall 4 55 ft (17 m) 8 ft (2.4 m)
Through the Wall 5 50 ft (15 m) 12 ft (3.5 m)
Through the Roof 1 70 ft (21.5 m) 2 ft (.6 m)
Through the Roof 2 65 ft (20 m) 3 ft (.9 m)
Through the Roof 3 60 ft (18.5 m) 5 ft (1.5 m)
Through the Roof 4 55 ft (17 m) 8 ft (2.4 m)
Through the Roof 5 50 ft (15 m) 12 ft (3.5 m)
NOTE: When using 4” (10.1 cm) PVC, use a 4” (10.1 cm) to 3” (7.6 cm)
reducer and exit the building wall with 3” (7.6 cm) PVC using the 3” (7.6
cm) 90° vent terminal supplied. Two 45° elbows are equivalent to one 90°
elbow.
Figure 2