Specifications

34
PARTS LIST
PART NAME AND DESCRIPTION
1. Blower Assembly 11. Diptube Nipple
2. Temperature Switch 12. Anode Nipple
3. Pressure Switch 13. Thermostat (Behind Cover)
4. Flue Baffle 14. T & P Relief Valve Opening
5. Honeywell Smart Valve 15. Pilot Assembly
6. Drain Valve 16. Cast Iron Burner
7. Fiberglass Insulation 17. Main Burner Orifice
8. Foam Insulation 18. Gas Feedline
9. Outer Door 19. Air Shutter (Cast Iron Only)
10. Thermostat Cover 20. Steel Burner
THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF:
GAS WATER HEATERS SUITABLE FOR WATER (POTABLE)
HEATING AND SPACE HEATING
1. All piping components connected to this water heater for space heating
applications must be suitable for use with potable water. In Massachusetts,
space heating piping length must not exceed 50 feet.
2. Toxic chemicals, such as those used for boiler treatment, must not be
introduced into potable water used for space heating.
3. This water heater must not be connected to an existing heating system or
component(s) previously used with a non-potable water heating appliance.
4. When the system requires water for space heating at temperatures higher
than required for other means, such as an ASSE approved mixing valve shall
be installed to temper the water for those uses in order to reduce the scald
hazard potential.
Please refer to the illustration on next page for the suggested piping arrangement.
CAUTION
THE COIL PROVIDED IN THIS WATER HEATER IS MANUFACTURED USING AN ALUMINUM
ALLOY INNER WALL, CROSS-LINKED POLY- ETHYLENE OUTER WALL AND NITRILE/HDPM
“O” RING(S).
DO NOT USE COMPONENTS OR MATERIALS WHICH MAY NOT BE COMPATIBLE WITH THESE
MATERIALS. THIS MAY CAUSE PREMATURE FAILURE OF THE COIL AND/OR THE WATER
HEATER.