Specifications

8
Installation (Minimum Clearances) continued-
Minimum Clearances
This installation shall allow access to the front of the water heater and adequate
clearance shall be provided for servicing and operating this water heater. The
water heater may be installed on either a combustible or non-combustible floor. If
the water heater is to be installed directly on carpeting, it shall be installed on top
of a metal or wood panel extending beyond the full width and depth of the
appliance by at least three (3) inches (7.6 Cm) in any direction or, if the appliance
is to be installed in an alcove or closet, the entire floor shall be covered by the
panel. The minimum clearances to combustibles for this water heater is: zero (0)
inch (0 cm) from the sides and rear, five (5) inches (12.7 cm) from the front of the
jacket, zero (0) inch (0 cm) from the vent connector and fifteen (15) inches (38.1
cm) from the jacket top.
Venting
WARNING
The venting system must be installed properly following all local codes or in the
absence of local codes, the latest edition of the National Fuel Gas Code (ANSI
Z223.1- latest edition), or in Canada, The Natural Gas and Propane Installation
Code (B149.1-00 latest edition). Failure to properly install the venting system
could result in property damage, personal injury, or death.
Figure 1.
Vent Terminal Clearances (Other than Direct Vent or “Power Vented” Installations)
WARNING
Failure to adhere to these installation and operating instructions may
create a hazard to life and property and will nullify the warranty.