Installation / Operation Instruction Manual

26
SECTION IX: OPERATING INSTRUCTIONS
WARNING
Water heaters are heat-producing appliances. To avoid damage or injury there must be no materials stored
against the water heater or vent system, and proper care must be taken to avoid unnecessary contact
(especially by children) with the water heater and vent system. UNDER NO CIRCUMSTANCES SHOULD
FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT THINNER BE USED OR STORED IN THE
VICINITY OF THIS WATER HEATER OR IN ANY LOCATION FROM WHICH FUMES COULD REACH THE
WATER HEATER.
Installation or service of this water heater requires ability equivalent to that of a licensed tradesman in the field
involved. Plumbing, air supply, venting, gas supply and electrical work are required.
Light the unit in accordance with the operating instructions label attached to the water heater.
Under NO circumstances should the input rate exceed the input rate shown on the water heater rating plate.
Over firing could result in damage or sooting of the water heater.
If the unit is exposed to the following, DO NOT operate water heater until all corrective steps have been made
by a factory authorized independent service contractor or qualified service professional.
2. Flooding to or above the level of the burner or controls 2. External firing
3. External firing 4. Damage
5. Firing without water 6. Sooting
NEVER OPERATE THE WATER HEATER WITHOUT FIRST BEING CERTAIN IT IS FILLED WITH WATER
AND THAT A TEMPERATURE AND PRESSURE RELIEF VALVE IS INSTALLED IN THE RELIEF VALVE
OPENING OF THE WATER HEATER.
General Instructions
To Fill the Water Heater
1. Close the water heater drain valve. This water
heater utilizes a ball valve; when closing the
valve, the stem will spin indefinitely. Confirm it
is closed by ensuring the slot on the stem is
perpendicular to the valve body. If alternative
water connections are provided but not used,
make certain they are plugged (i.e. space
heating & alternate top connections).
2. Open the cold-water supply shut-off valve.
3. Open several hot water faucets to allow air to escape from the system.
4. When a steady stream of water flows from the faucets, the water heater is filled. Close the faucets and
check for water leaks at the water heater drain valve, combination temperature and pressure relief valve
and the hot and cold-water connections.
Sequence of Operation
1. Thermostat starts with heating cycle.
2. Blower turns ON.
3. Blower pre-purge at reduced speed.
4. Spark rod sparks to the burner and gas valve opens, then the burner ignites.
5. Flame signal confirmed with main burner ON.
6. Blower remains at reduced speed for a short period to stabilize flame.
7. Blower increases to full speed for full input.
8. Thermostat becomes satisfied.
9. Gas valve closes, then the main burner turns OFF.
10. Blower post-purges, then turns OFF.