Service Manual

5
5
Tools Required for Service
Manometer: Two types available, a liquid “U” tube type or a digital (magna-helic) type. This device
is used to measure gas and/or air pressures and vacuum.
Multi-Meter: A digital type is strongly recommended. This device is used to measure electrical
values. The meter you select must have the capability to measure volts AC, volts DC, Amps, micro-
amps and ohms.
Thermometer: Used to measure water temperature. An accurate thermometer is recommended.
Water Pressure Gauge: Used to measure water supply pressure. Also used to determine tank
pressure by adapting to the drain valve of the heater.
Jumper Leads: A length of wire (12" min.) with alligator clip at both ends.
Various Hand Tools: Pipe wrench, channel locks, open end wrench set, 12" crescent wrench,
Allen wrench set, Torx bit set, screwdrivers (common & Philips), long reach (12") magnetic tip
Philips head screwdriver #2 tip, ¼" nut driver, pliers (common & needle nose), socket set including
a 1-1/16 deep well socket, wire cutters, wire strippers, wire crimpers, torpedo level, small shop vac,
step ladder, and flashlight.
Features
Features of ICON System Control
Digital water heater display on control panel for setting and displaying the temperature setpoint.
Pressing temperature UP and DOWN buttons changes the temperature setpoint. Temperature
format may be displayed in °F or °C.
Single control board with plug in wiring controls temperature, ignition, and blower operation.
Reduced number of parts for servicing and wiring.
Plug in wiring reduces chance of miswiring.
Burner ignition with direct spark ignition - A high voltage spark jumps from the spark rod to the
burner surface to ignite the gas. Eliminates burned out hot surface igniter replacements.
Water heater display will show diagnostic codes in the event the water heater needs servicing.
Aids in diagnosing and servicing the water heater.
Water heater display can show previous error code history to further aid in servicing the water
heater.