Assembly and Installation Instructions

ASSEMBLY AND INSTALLATION
INSTRUCTIONS
NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements.
2. READ AND SAVE THESE INSTRUCTIONS.
WARNING:
TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF
POWER BEFORE INSTALLING OR SERVICING THIS FIXTURE.
Turn off the power at fuse or circuit box.
Installation Steps
Turn on the power at fuse or circuit box.
Wire Connector (B)
Fitter Screw (A)
Hardware Package (included):
Grounding Wire
Fixture Wire
Wire Connector (B)
Post
Fixture
Cover
Threaded Pipe
Fitter
Fitter Screw(A)
Finial
1. Carefully unpack the fixture. Lay out all parts on a clean surface.
2. Take out the fixture, Remove the finial and rubber pad, and then
remove the cover from the fixture. Remove the iron plate from fixture
by unscrew the two set screws.
3. Before installing the fixture, then remove the foam / bubble bag
from the fixture.
4. Install a bulb (not included). Check relamping label at socket
area or packaging for maximum allowed wattage.
5. Attach the iron plate to the fixture, secure it with two set screws.
6. Place the cover over the fixture, making sure the threaded pipe
feed through the holes of cover, then screw cover with the rubber
pad and finial.
7. Pull out the source wires from the post. Make wire connections
using wire connectors as follow:
---Connect the hot wire (usually black insulation) from the fixture
to the black wire from the post
---Connect the neutral wire (usually white insulation) from the
fixture to the white wire from the post
---Attach the fixture grounding wire (usually green insulation or
bare wire) to the grounding wire from the post.
Carefully put the wires back into the post.
8. Place the fitter on the post, then secure it with the fitter screws.
IMPORTANT:
The sensor has an excellent photocell function
to enable the light to turn on at dusk and off at
dawn automatically.
Bulb Type T10 Max.60W
(not included)
Rubber Pad
Photocell
Iron Plate
Set Screw

Summary of content (2 pages)