Specifications

60GHzand80GHzProductsNMSManual
12 58000511rev.F
3. Select‘SubmitNewValues’atthebottomofthe‘Setup’page.Aredvaluewillbe
displayedundertheCurrentEffectiveValuescolumn.Clickthe‘Setup’tabtorefreshthe
browserwindowuntiltheCurrentEffectiveValueisnolongerdisplayedinred.
4.4 AdaptPath™SecondaryPath
WhenanAdaptPath™linkreachesapredefinedRSLlevel,thefibertrafficisdirectedtoa
secondarypathattachedtothecopperinterfacesuchasa5.4or5.8GHzPTPradiolink
TheFiberremainsoperationalandInBandmanagementwillstillbeavailable.
TheAdaptPath™capabilityshouldremaindisabledexceptinredundantlinkconfigurationsorif
itisnecessarytoquicklysignalexternalnetworkequipmentwhenradiolinkdownstatesare
detected.
TheAdaptPath™feature:
· IsonlyavailableinAdaptRate(AR)radiosfromBridgeWave
· RSLactivationpointsareconfiguredfromtheHighbandradiointheradiolink.
· TheLowbandradioLSPmustbeconfiguredasenabled.
· Usingthebuiltin‘ForceLSP’functionontheMaintenancepagecantestthe
functionality.
TheAdaptPath™functioncanbesetuptoallow:
· GEtoFEandthenfailoverbysettingtheRSLleveltothesuggestedFEdefault.
· GEtofailoverbysettingtheRSLleveltothesuggestedGEdefault.
· FlexibilitytosetanyRSLlevelfortheAdaptPath™failover.
TheCopperportontheBridgeWaveradiosissettoAutonegotiate(AN).Thefailoverradio
mustalsobesettoAN.Thenegotiationbetweenthetwodevicesshouldsettleat100BaseTFull
Duplex.
InBandmanagementisrequired,OutBandmanagementisnotavailablewithAdaptPath™
links.
DataoverthesecondarypathisNOTencryptedonAESequippedsystems