Figure45 OutBandManagementNetworkDeploymentExample
4.6.3 ConfiguringManagementAccess
Usethefollowingstepstoconfigurethe‘ManagementAccess’option:
1. Connecttothewebmanagementinterfaceoftheunitandselectthe‘Setup’tab.
2. Underthe‘AccessControl’sectionselectthedesired‘InBand(Default)’,or‘OutBand
(CopperManagementOnly)’option.
When‘InBand’isselectedtheinternalswitchisconfiguredsothatthecopper,fiber,and
radiointerfacesareplacedontothesameLANandtheoptiontoallowmanagement
accessontheFiberand/ortheradiointerfacebecomesavailable.
When‘OutBand’isselectedtheCopperinterfaceisplacedintoaseparateLANonthe
internalswitchandbecomesphysicallyisolatedfromthefiberandradiointerfaces.When
thisoptionisenabledthemanagementinterfaceoftheunitcanonlybeaccessedthrough