Specifications

60GHzand80GHzProductsNMSManual
60 58000511rev.F
15 DefaultReco very(HardReset)
Iftheunit’sAdministratorpassword orIPconfigurationisforgotten,itwillbenecessaryto
performahardresettoreturntheseparameterstothefactorydefaultvalues.Onlythe
Administrator/User/Factorypasswords,IPconfiguration,andManagementAccessparameters
willberesettodefaultvalues.Allotherparameterswillremainintheircurrentlyconfigured
state.
EachBridgeWaveunitisshippedwithahardresetboxthatcanbeusedtoreturntheunittoits
defaultfactoryconfiguration.
InordertoresettheAdministratorpassword andIPconfiguration,itisrequiredtohavephysical
accesstotheunit’scopperdataport(RJ45jack)orcableandtheunit’spowercable.
Userdatatraversingtheradiolinkwillbebrieflyinterrupted
duringthehardrestartprocess.
Procedure
1. Firstpowerdowntheunit,
2. Connectthehardresetboxviaastraightthrough(standard)Ethernetcableatleast3
meterslongtothecopper(RJ45)portontheunit.Ifacableisalreadyrunningtothe
RJ45portoftheunit,theresetboxcansimplybeconnectedtotheotherendofthis
cable.
3. Reconnectpowertotheunitandwaitaminimumof90seconds,before
disconnectingthehardresetbox.Theunitwillthenbeginitsnormalrestartcycle,and
themanagementagentwillnormallybecomeaccessiblewithinapproximately 3
minutesusingthedefaultIPconfiguration,usernames,passwordsandcommunity
strings.
Thismaytakelongerthanthenormal140seconds fortherestart
operationtocompleteandthemanagementagenttobecome
available.