Manual

CordSets andReceptacles
Use only high quality, well-insulated, grounded extension
cords with the generator's 120 Volt duplex receptacle.
Inspect extension cords before each use.
Checkthe ratings of all extension cords beforeyou use
them. Extension cord sets used should be rated for 125 Volt
AC loads at 20 Amps or greater for most electrical devices.
Some devices, however, may not require this type of
extension cord. Checkthe operator's manuals of those
devices for the manufacturer's recommendations.
Keepextension cords as short as possible to minimize
voltage drop.
_i_WARNING Damagedor overloaded electrical cords
could overheat, arc, and burn resulting in death,
serious injury, and/or property damage.
ONLYuse cords ratedfor your loads.
Follow all safeties on electrical cords.
Inspect cord sets before each use.
120/240 Volt AC, 30 Amp, LockingReceptacle
Use a NEMA L14-30 plug with this receptacle.Connect a
4-wire cord set rated for 250 Volt AC loads at 30 Amps (or
greater). You can use the same4-wire cord if you plan to
run a 120 Volt load.
4-Wire Cord Set
(Neutral)
Y(Hot) / X(Hot)
NEIVlAL14-30 /-7[-7 Ground (Green)
This receptaclepowers 120/240 Volt AC, 60 Hz, single phase
loads requiring up to 5,500 watts of power (5.5 kW) at
22.9 Amps for 240 Volts or two independent 120 Volt loads
at 22.9 Amps each. Theoutlet is protected by a two pole
rocker switch circuit breaker.
120 Volt AC, 20 Amp, Duplex Receptacles
The duplex receptaclesare protected against overload by a
two pole rockerswitch circuit breaker.
Useeach receptacleto operate 120 Volt AC, single-phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at
20 Amps of current. Usecord sets that are rated for 125 Volt
AC loads at 20 Amps (or greater). Inspect cord sets before
each use.
GeneratorAdapter CordSet
The generator comes with a 25' generator adaptercord set
designed to provide two sets of 120 Volt, 20 Amp outlets
from one 120 Volt, 20 Amp duplex receptacle.
The maximum load on each outlet is 20 Amps. The
maximum total load on both red dot outlets or blue dot
outlets is 20 Amps.
NOTICE Follow all safety precautionswhen connecting any
extension cord or deviceto the generator.
NOTICE Receptacles may be marked with rating value
greater than generator output capacity.
NEVERattempt to power a device requiring more amperagethan
generator or receptaclecan supply.
DONOToverloadthe generator. SeeDon't OverloadGenerator.
11