Dimensions Guide

Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
Broan-NuTone Canada Mississauga, Ontario www.broan.ca 877-896-1119
EI59 SERIES WIRING
EI59 SERIES MOUNTING
1. Determine length “L” of frame assembly based upon desired
installation height. (See chart below.) To adjust frame
assembly height, remove (8) screws, slide upper frame
assembly to required height, replace screws and tighten
securely.
LENGTH
“L
2. After ceiling surface is finished, align frame assembly to
ceiling framing, and attach to ceiling framing with (6) 4mm x
38mm screws. Tighten securely, making sure that the upper
frame bracket is tight against the ceiling.
24" 25" 26" 27" 28" 29" 30" 31" 32" 33" 34" 35" 36"
Ceiling
Height
8 Feet 19-5/8” 18-5/8” 17-5/8” 16-5/8” 15-5/8”
9 Feet * 23-5/8” * 22-5/8” * 21-5/8” * 20-5/8”
9 Feet
with
FXNE59SS
32-5/8" 31-5/8" 30-5/8" 29-5/8" 28-5/8" 27-5/8" 26-5/8"
10 Feet
with
FXNE59SS
44-5/8" 43-5/8" 42-5/8" 41-5/8" 40-5/8" 39-5/8" 38-5/8" 37-5/8" 36-5/8" 35-5/8" 34-5/8" 33-5/8" 32-5/8"
* Non-duct recirculation louvers will be exposed in ducted configuration
Desired Hood Distance (Above 36" High Cooktop)
Frame Length “L”
* 20-5/8"
FRONT
CEILING
MATERIAL
IS INSTALLED.
CEILING
FRAMING
ABOVE -
SHOWN
AS DOTTED
LINES.
1. Remove wiring cover and connect house wiring to hood
wiring black to black, white to white, green to green. Re-
attach wiring cover.
FRONT
NOTE: Minimum hood distance above cooktop must not be less than 24”.
A maximum of 36” above the cooktop is highly recommended for best capture of cooking impurities.
Distances over 36” are at the installer and user’s discretion; and if ceiling height and flue length permit.
9-ft. to 10-ft. ceilings may require 10-ft. Flue Extension Model FXNE59SS, depending on installation heights (purchase separately).