Technical data

Brocade 6910 Ethernet Access Switch Diagnostic Guide 31
53-1002348-02
Connectivity Fault Management
This example shows all MEPs configured on this device for maintenance domain rd.
Console#show ethernet cfm maintenance-points local mep
MPID MD Name Level Direct VLAN Port CC Status MAC Address
---- ---------------- ----- ------ ---- -------- --------- -----------------
1 rd 0 UP 1 Eth 1/ 1 Enabled 00-12-CF-3A-A8-C0
This command displays detailed CFM information about a specified local MEP in the continuity
check database.
show ethernet cfm maintenance-points local detail mep
Syntax: show ethernet cfm maintenance-points local detail mep [domain domain-name |
interface interface | level level-id]
domain-name – Domain name. (Range: 1-43 alphanumeric characters)
interface – Displays CFM status for the specified interface.
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-12)
port-channel channel-id (Range: 1-12)
level-id – Maintenance level for this domain. (Range: 0-7)
This example shows detailed information about the local MEP on port 1.
Console# show ethernet cfm maintenance-points local detail mep interface ethernet
1/1
MEP Settings:
-------------
MPID : 1
MD Name : vopu
MA Name : r&d
MA Name Format : Character String
Level : 0
Direction : Up
Interface : Eth 1/ 1
CC Status : Enabled
MAC Address : 00-E0-0C-00-00-FD
Defect Condition : No Defect
Received RDI : False
AIS Status : Enabled
AIS Period : 1 seconds
AIS Transmit Level : Default
Suppress Alarm : Disabled
Suppressing Alarms : Disabled