Technical data

32 Brocade 6910 Ethernet Access Switch Diagnostic Guide
53-1002348-02
Connectivity Fault Management
This command displays detailed CFM information about a specified remote MEP in the continuity
check database.
show ethernet cfm maintenance-points remote detail
Syntax: show ethernet cfm maintenance-points remote detail
{mac mac-address | mpid mpid}
[domain domain-name | level level-id | ma ma-name]
mac-address – MAC address of a remote maintenance point.
This address can be entered in either of the following formats: xx-xx-xx-xx-xx-xx or xxxxxxxxxxxx
mpid – Maintenance end point identifier. (Range: 1-8191)
domain-name – Domain name. (Range: 1-43 alphanumeric characters)
level-id – Authorized maintenance level for this domain. (Range: 0-7)
ma-name – Maintenance association name. (Range: 1-45 alphanumeric characters)
This example shows detailed information about the remote MEP designated by MPID 2.
Console# show ethernet cfm maintenance-points remote detail mpid 2
MAC Address : 00-0D-54-FC-A2-73
Domain/Level : voip / 3
MA Name : rd
Primary VLAN : 1
MPID : 2
CC Lifetime : 645 seconds
Age of Last CC Message : 2 seconds
Frame Loss : 137
CC Packet Statistics : 647/1
Port State : Up
Interface State : Up
Crosscheck Status : Enabled
This command displays CFM continuity check errors logged on this device.
show ethernet cfm errors
Syntax: show ethernet cfm errors [domain domain-name | level level-id]
domain-name – Domain name. (Range: 1-43 alphanumeric characters)
level-id – Authorized maintenance level for this domain. (Range: 0-7)
This example shows a continuity check error logged for this device.
Console# show ethernet cfm errors
Level VLAN MPID Interface Remote MAC Reason MA Name
----- ---- ---- --------- ----------------- ---------------- ----------------
5 2 40 Eth 1/1 ab.2f.9c.00.05.01 LEAK provider_1_2