Raster Command Reference

Brother PJ-600/700/800 Series Command Reference
20
© 2015 Brother Industries, Ltd. All Rights Reserved.
5.2. Command details
Name
Invalid command
Syntax
NULL
00 H
Description
Skip
If data transmission should be stopped midway, send the “initialize” command after
sending the “invalid” command for the appropriate number of bytes to return to the
receiving state, where the print buffer is cleared.
Name
Switch command mode
Syntax
ESC + i + a + {n1}
1B H + 69 H + 61 H + {n1}
Description
Switches between the machine's command modes. A machine that receives this
command operates in the specified command mode until the machine is turned off.
Definition of {n1}:
0ESC/PRaster default
1: Maintenance Mode
3P-touch Template
Name
Initialize
Syntax
ESC + @
1B H + 40 H
Description
Initializes the print buffer.
Name
Status information request
Syntax
ESC + i + S
1B H + 69 H + 53 H
Description
Status information is transmitted.
Name
Set 2-ply mode
Syntax
ESC + ~ + p + {n1} + null
1B H + 7E H + 70 H + {n1} + 00 H
Description
Specifies whether or not the strobe time is extended and the print density is adjusted
when 2-ply paper is used.
Definition of {n1}:
0: Disable (default)
1: Enable