CPCL Emulation Command Reference

7
2.8 Advanced Commands
Function CPCL Description
CONTRAST
{level}
{level}: Contrast level
0: Default
1: Medium
2: Dark
: Very Dark
Specify the print darkness for the entire label.
The TONE and CONTRAST commands
cannot be used together.
TONE
TONE
{level}: select a value from -99 to 200
Specify the print darkness for all labels. The
TONE and CONTRAST commands cannot
be used together.
CENTER
Center all subsequent fields.
LEFT
Left-align all subsequent fields.
RIGHT
Right-align all subsequent fields.
PAGE-WIDTH
Specify the page width.
WAIT
Pause after a label is printed.
SPEED
Set the highest motor speed level.
SETSP
SETSP {spacing}
Change the spacing between text characters.
The default spacing is zero.
ON-FEED
ON-FEED {action}
Ignore, form-feed, or reprint the last label
when the Feed key is pressed or when it
receives the form-feed character (0x0c).
PRESENT-AT
PRESENT-AT {length} {delay}
Position the media on the Tear bar of the
printer or at a location where the printed label
can be easily removed by the operator.
BEEP
Sound the beeper for a given time length.
2.9 Line Print Mode
Function CPCL Description
BEGIN-PAGE
! U1 BEGIN-PAGE <cr><lf>
Clear line print memory and line print
information to initialize a line print session.
END-PAGE
Close a line print session and print the