User Manual

2. Locating a hot spot aim the thermometer outside the
area of interest, then scan across with up and down
motions until you locate the hot spot.(please turn on
the laser to for accurate measuring)
3. Diagram description
(1) Trigger Press for turn on, and then display test
result and hold data 7 seconds automatically
("HOLD") after unclamping switch. Trun off
automatically after 10 seconds without operate.
(2) Laser pointer button press it for turn on laser
pointer, press again for turn off.
(3) Back light /Up button In Alarm temperature” and
“setting emissivity” mode for adjust value up. In
other mode for turn on back light.When product
working, press it for turn on back light, press again
for turn off.
(4) MODE button Press MODE button for cycle
options - MAX - AVG - MIN –HAL –LAL mode
AMAXMeasure maximum data current
BMINMeasure minimum data current
CAVGCalculate the average of all measure data
DHALAlarm of high temperature. Option HAL
mode, press UP/DN button for set alarm
temperature. When LCD display ”H” means
measure result exceeded the alarm temperature
ELALAlarm of low temperature. Option HAL
mode, press UP/DN button for set alarm
temperature. When LCD display ”L” means
measure result under the alarm temperature
(5) T/ DN button In Alarm temperature” and “setting
emissivity mode for adjust value down . When turn
on product and press direct for
/
0
F select.
(6) SET buttonPress for setting emissivity . And press
“UP/DN for adjust from 0.1~1.0. Press SET button
again for exit setting mode .
(7) LCD
(8) Battery door: When replace battery door, please
using the finger indents to pull open the battery
door.
3
Maintenance
1) Lens cleaning: Blow off lose particles using clean
compressed air. Gently brush remaining debris away
with a moist cotton cloth.
2) Case cleaning: Clean the case with a damp
sponge/cloth and mild soap.
3) Please take out the battery when not using for a long
time.
Note:
1) Do not use solvent to clean lens.
2) Do not submerge the unit in water.
4
specifications
Temperature
range
-50
to 700
(-58 to1292
0
F)
Accuracy
±3% or ±3of rdg,-50 to 0(-58 to 32
0
F)
±2% or ±2 of rdg, 0 to 100(32 to 212
0
F)
±3% or ±3 of rdg, ≥100(212
0
F)
Repeatability
1%of reading or 1
Response time
500msec, 95%response
Spectral response
8-14um
Emissivity
0.11.0 adjustable
Ambient operating
range
0 to ~60(32 to 140
0
F)
Relative humidity
10-95% RH noncondensing
Storage temperature
-20~60
(-4~140
0
F) without battery
Ambient temp range
of guarantee for
accuracy
23
~28
Weight/dimensions
155g;170
×
87
×
44mm
Power
9V battery ,6F22 or NEDA 1604
Battery life
Laser models:12hrs
distance spot ratio
16:1
Note:
Display “AL” means Ambient temp lower than 0”;
Display “AH” means Ambient temp higher than 60”;
Display above code in normal Ambient temp, probable
means this meter was broken.
Attached list Applicable Emissivity for
Different Material ( For reference only)
Material
Emissivity
Emissivity
Asphaltum
0.90 to 0.98
0.98
Beton
0.94
0.98
Cement
0.96
0.75 to 0.80
Sand
0.90
0.96
Soil
0.92 to 0.96
0.80-0.95
Water
0.92 to 0.96
0.97
Ice
0.96 to 0.98
0.94
Snow
0.83
0.85-0.95
Glass
0.90 to 0.95
0.90
Ceramic
0.90 to 0.94
0.70-0.94
Marble
0.94
0.81
Gypsum
0.80 to 0.90
0.78
Compo
0.89 to 0.91
0.78 to 0.82
Brick
0.93 to 0.96
0.2-0.3
Above picture and content just for your reference.
Please be subject to the actual products if anything
different or updated. Please pardon for not informing in