P1136
10841 020503
Dial Timer
DIGITAL BREW TIMER (Late Models)
FIG. 21 DIGITAL BREW TIMER
SERVICE (cont.)
DIAL TIMER (Early Models) (cont.)
Location:
The timer is located inside the front of the trunk
on the upper right side of component bracket.
Test Procedure (Digital Timer):
NOTE: Do not remove or install wires while timer board
is installed. Pressure applied to one side may cause
damage to the board.
1. Disconnect the brewer from the power source and
remove the front access panel.
P2203.45
2. Remove the #8-32 screw securing circuit board
to the mounting bracket.
3. Remove circuit board and spacers (as required).
4. With a voltmeter, check the voltage across terminals
TL1 and TL2 when the "ON/OFF" switch is in the
"ON" position. Connect the brewer to the power
source. The indication must be:
a) 120 volts ac for two wire 120 volt models and
three wire 120/240 volt models.
b) 200 to 230 volts ac on two wire 200 volt or
230 volt models.
5. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #6.
If voltage is not present as described, refer to the Wiring
Diagrams and check the brewer wiring harness.
6. With a voltmeter, check the voltage across terminals
TL1 and TL4 when the "ON/OFF" switch is in the
"ON" position. Connect the brewer to the power
source. The indication must be 0 volts.
If voltage is as described, proceed to #7.
If voltage is not as described, disconnect the brewer
from the power source and replace the timer.
7. With a voltmeter, check the voltage across ter-
minals TL1 and TL4 when the "ON/OFF" switch
is in the "ON" position. Connect the brewer to the
power source and press the "START" switch. The
indication must be as follows:
a) 120 volts ac for two wire 120 volt models and
three wire 120/240 volt models.
b) 200 to 230 volts ac on two wire 200 volt or
230 volt models.
If voltage is present as described, the brew timer is
operating properly. Reset the timer as required, to
obtain the desired brew volume.
If voltage is not present as described, disconnect the
brewer from the power source and replace the timer.
Removal and Replacement (Digital Timer):
1. Remove the #8-32 screw securing circuit board
to the mounting bracket.
2. Remove circuit board and spacers (as required).
3. Remove all wires from the timer.
WHI to Solenoid Valve
BLK to Solenoid Valve
To Main Wiring Harness