Specifications

Page 24
NO-NAME LEFT, along with MODIFY, SHOW and
NEXT (DUAL brewers).
3. Press and release NEXT to advance to the desired
coffee name to be modified.
4. Press and release MODIFY. The display should
read BREW OZ.
5. Press and release DONE. The display should read
3 BATCHES DONE?.
6. Press and release YES. The display should now
read % BYPASS.
7. Press and release DONE. The display should read
3 BATCHES DONE?.
8. Press and release YES. The display should now
read SET PULSE BREW.
9. Press and release YES. The display should now
read SELECT METHOD.
10. If setting pulse brew using EASY METHOD (brewing
into a funnel) press EASY then NEXT and proceed
with the setup instructions for SET PULSE BREW
- EASY METHOD.
11. If setting pulse brew by MANUAL METHOD (enter-
ing known times) press MANUAL then NEXT and
proceed with the setup instructions for SET PULSE
BREW - MANUAL METHOD.
PROGRAMMING FUNCTIONS - (cont.)
SET PULSE BREW (cont.)
41343 043012
SET PULSE BREW - EASY METHOD
NOTE: The procedure to enter the PULSE BREW
function must be performed prior to following the
steps listed below.
1. The display should read BREW TIME: X.XX and
a batch size indicator will be flashing.
2. Using (-) and (+), set the desired brew time for
the selected batch size.
3. When finished, select another batch size to be set
by pressing the switch next to the indicator light.
Repeat step 2 for each batch size to be set.
4. When finished setting all batch sizes, press done.
This will display the 1st, OFF, and LAST times for
5 seconds, then advance to 3 BATCHES DONE ?.
5. If the three batch sizes are not correct, press and
release NO to return to SELECT METHOD setup
screen and repeat steps 2 thru 4. If they are cor-
rect, press YES. This will advance to the DRIP
TIME setup. (See DRIP TIME SET UP)
SET PULSE BREW?
NO YES
DRIP TIME XX.X
(-) DONE (+)
SELECT METHOD
EASY NEXT MANUAL
BREW TIME: X:XX
(-) DONE (+)
3 BATCHES DONE?
NO YES
1st OFF LAST
X:XX X:XX X:XX
5 sec delay
EASY SELECTED