Specifications

Page 28
ENABLE ADS?
This function allows the operator to choose whether
or not to display the advertising message that was en-
tered into the brewer with an AD CARD. This message
will be displayed when the brewer is not in use.
Procedure to Enable/Disable Ads:
1. Press and hold upper right hidden switch until the
display reads UNITS. Release switch. Continue to
press and release switch until the display reads
ENABLE ADS. The YES or NO will be flashing to
indicate the current selection.
2. Press and release the NO to disable this function
(no ads will be displayed on the screen), or;
3. Press and release the YES to enable this function
(ads will be displayed on screen).
4. When finished, press and release DONE to save
the new setting, exit the ENABLE ADS function and
advance to the next function screen, SET TEMP.
Another alternative is to press and release the
ON/OFF switch (either on DUAL brewers) located
on the front switch panel to exit the ENABLE ADS
function and return to the MAIN SCREEN.
SET TEMP - Range: 185˚F (85˚C) to 205˚F (96˚C)
This function allows the operator to set the brew
water temperature in the tank. It also sets the hot
water faucet dispense temperature.
PROGRAMMING FUNCTIONS - (cont.)
Procedure to set brew temperature:
1. Press and hold upper right hidden switch until the
display reads UNITS. Release switch. Continue to
press and release switch until the display reads
SET TEMP.
2. To adjust the brew temperature, press (-) to de-
crease or (+) to increase the brew temperature.
3. When finished, press and release DONE to save
the new setting, exit the SET TEMP function and
advance to the next function screen, SET READY.
Another alternative is to press and release the ON/
OFF switch (either on DUAL brewers) located on
the front switch panel to exit the SET TEMP func-
tion and return to the MAIN SCREEN.
SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C)
This function allows the operator to set the mini-
mum temperature allowable to start a brew cycle. The
range can be from 185˚F (85˚C) to within 2˚F (-1.7°C)
of the SET TEMP. The water must be at the SET READY
temperature or higher for the display to indicate READY
TO BREW. If brew lockout is enabled, the brewing pro-
cess will not start below this READY temperature.
NOTE: The upper limit for SET READY temperature
is 2˚F (-1.7°C) less than the water temperature (SET
TEMP) setting.
-1000 213.8 101.0 200 93.3
-500 212.9 100.5 200 93.3
0 212.0 100.0 200 93.3
500 211.1 99.5 200 93.3
1000 210.2 99.0 200 93.3
1500 209.3 98.5 200 93.3
2000 208.4 98.0 200 93.3
2500 207.4 97.4 200 93.3
3000 206.5 96.9 199 92.8
3500 205.6 96.4 198 92.2
4000 204.7 95.9 197 91.7
4500 203.8 95.4 196 91.1
5000 202.9 94.9 195 90.6
5500 201.9 94.4 195 90.6
6000 201.0 93.9 194 90.0
6500 200.1 93.4 193 89.4
7000 199.2 92.9 192 88.9
7500 198.3 92.4 191 88.3
8000 197.4 91.9 190 87.8
8500 196.5 91.4 189 87.2
9000 195.5 90.8 188 86.7
9500 194.6 90.3 187 86.1
10000 193.7 89.8 186 85.6
Brew water temperature is factory set at 200 F (93.3 C)
Areas of high altitude will require lowering this tempera-
ture to prevent boiling. This chart should be used as a
guide when readjusting the brew water temperature.
Altitude
(Feet)
Boiling point
of water
F C
Recommended
water temperature
F C
NOTICE
35665.0000A 05/04 © 2004 Bunn-O-Matic Corporation
ENABLE ADS ?
NO DONE YES
SET TEMP: XXX°
(-) DONE (+)
SET READY: XXX°
(-) DONE (+)
41343 080108