Troubleshooting guide

JDF Silver Series Training Manual
20
Preventive Maintenance
In order to maintain proper operation and long service life BUNN recommends performing the preventive mainte-
nance every 6 months. Individual customers will vary with some customers choosing not to receive preventive main-
tenance. Some of the PM items may require more frequent maintenance depending on the site conditions.
Tools Required:
• Standard screwdriver
• 8 inch crescent wrench (2)
• Needle Nose Pliers
• Velcro Tape
• Graduated measuring cup
• Refractometer
• Thermometer
• Flashlight
• 5 gal. bucket
• Tube PM Kit BUNN PN: 39690.0000 (1 per dispense station)
• Kay-5Sanitizer(50CountBUNNP/N:24634.0001)(200CountBUNNP/N:24634.0000)
• BUNNrellablecontainer(BUNNP/N:39302.0000)
• Condenser Cleaner
• Rubber gloves
• Safety goggles or face shield
• Fin Comb
• Mild non abrasive detergent and cloth
• Vacuum with soft brush attachment
Prior to servicing the dispenser:
• Sanitizethedispenserbeforeyoubeginthepreventivemaintenanceprocess.
• Disconnect the water and electrical supply.
• Assess placement of dispenser to perform PM process.
• Check and make sure you have the necessary safety equipment for cleaning the condenser.
• Remove the lower splash panel.
• Remove the right side panel.
PM Steps
Step1:Removeinletvalveconnectorttingandcleaninletvalvestrainer.
□ Usingyourhandandunscrewthevalveadapterttingandsetaside.
Using the needle nose pliers gently grab the strainer tab and pull the strainer out of the valve.
Clean and rinse strainer of any sediment or mineral build-up.
Re-installation is the opposite of removal.
Step 2: Replacement of lamp in lighted door assembly.
□ Usingastandardscrewdriver,removethevescrewssecuringtheouterdoorcovertotheinnerdoor.
Disconnect the door switch connector or connectors from the auxiliary switch CBA and set door cover aside.
Gently grab the failed lamp and rotate half turn until lamp connection studs are aligned up with lamp socket
opening and remove lamp.
Re-installation of new lamp is the opposite of removal.
Step3:Removeandcleanthemeshairlter.
□ Usingyourhand,grabthemeshltertrianglehandleandpulltheairlterfromthedispenser.
□ Washtheairlterinwarmsoapywateranddry.
□ Usingaashlight,shinethelightthroughthecondensertocheckfordirtbetweenthens.Inspectcondenserns
for straightness. Go to the next step of Cleaning the Condenser.
□ InspectVelcrostrapsforadhesiontoairlteranddispenserandbereadytoreplaceaftercleaningofthe
condenser.
Step 4: Cleaning the condenser.
□ Usingasoftcleaningbrushattachment,gentlyvacuumthecondensercoilns.