Troubleshooting guide

JDF Silver Series Training Manual
22
Total Dispense Test
Step 1:Placethepitcherbeneaththedispensenozzleyouaretesting.
Step 2: Place the “Dispense Lockout” switch in the Off position and access the internal program switch and
turn ON.
Step 3: Press and release the dispense button, (“Stop/Plus” button if using portion control option), 6 times.
Step 4: Measure the amount of liquid dispensed.
Step 5: Mark the quantity of liquid dispensed on the total dispense ratio chart.
Pump Speed Adjustment
Step 1: Disconnect the machine from the power source.
Step 2: Remove the drip tray.
Step 3: Remove the splash panel by removing the screws holding it in place.
Step 4: Locate the adjustment knobs on the control board. Turn the knob, associated with the dispense
station you wish to adjust, clockwise to increase the pump speed and counterclockwise to decrease
the pump speed. Increasing the pump speed will increase the amount of product dispensed giving
you a higher total dispense, decreasing the pump speed will have the opposite affect.
Step 5: Conduct the total dispense test to determine if more of an adjustment is needed. If no further
adjustments are required, turn OFF the program switch and re-install the lower splash panel.
Temperature Compensated Refractometer Method
Step 1:AdjustthewaterowasdescribedinWaterFlowTestandAdjustment.
Step 2:Placeanemptycontainerundertheappropriatedispensenozzle.
Step 3:Pressandholdthe“ProductDispenseSwitch”,untilwaterandconcentratebeginowingfreelyfrom
thedispensenozzle.
Step 4: Discard the product caught previously and place the empty container back under the dispense
nozzle.
Step 5:Pressandholdthe“ProductDispenseSwitch”untilthecupislled.
Step 6: Stir the contents of the cup, and use the refractometer (according to the manufacturer’s instructions)
to check the brix %.
Step 7: Adjust the pump speed (down to decrease the brix %; up to increase the brix %) to achieve the
correct brix % as described in Pump Speed Adjustment.
Step11:IfcustomerhasaBUNNwaterltrationsysteminstalledbeforethedispenser,replacethelterorltercar-
tridge.