User's Manual

Page 46
TROUBLESHOOTING (cont.)
Problem
Possible Cause
Troubleshooting Procedures
Check the sensitivity setting. Refer
to the Refill function. If the left
three digit number is less than the
right number, the machine “thinks”
it is full and the refill valve should
be off. If the left number is larger
than the right, then the refill valve
will automatically be turned on to
fill the tank. The right number is
the threshold setting and can be
adjusted to compensate for extreme
water conditions: very pure, low
conductance water requires a higher
setting, while high mineral content,
high conductance water requires
a lower setting. Note that the left
number changes from a high value
when water is NOT touching the refill
probe to a low value when water IS
touching the probe. For best opera-
tion, the right number should be set
to a value midway between these low
and high numbers. Before changing
the setting, confirm that the refill
probe is free of scale buildup and
the connection to it is secure.
Substitute a control board known to
be in good working order.
Remove power from the brewer.
Press reset button on limit ther-
mostat. Then check for continuity
through it.
Remove power from the brewer.
Check for continuity through the
tank heaters.
1. Refill Probe or Sensitivity Set-
ting
2. Electronic Control Board
1. Limit Thermostat
CAUTION - Do not eliminate or
bypass limit thermostat. Use only
replacement part #23717.0001.
2. Tank Heaters
Water flows into tank continuously
with power applied to brewer.
Water will not heat or display shows
HEATING TIME TOO LONG
35879.1 071405