Product Manual

TROUBLE SHOOTING GUIDE CHECKLIST:
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where you’ve purchased the pump,
please contact us at 514 337-4415 , and ask for our sales department, and they will be pleased to help you
with any questions you might have, concerning your installation.
ACTION:
Turn switch to ‘ON’ position
Replace
Reset
Re-install
Clean
Check movement
Replace
Replace
Check voltage
Check drilled hole in discharge pipe
Wrong pump selection (over 15’)
Clean
Check voltage
Check drilled hole in discharge pipe
Wrong pump selection (over 15’)
Clean
Replace
Install valve
Clean debris
Check for movement
PROBABLE CAUSE:
Switch is ‘OFF’ position
Blown fuse
Tripped breaker
Disconnected plug
Corroded plug
Float stuck
Defective switch
Defective motor
Improper voltage
Pump may be airlocked
Pump discharge head too high
Clogged inlet/impeller
Improper voltage
Pump may be airlocked
Pump discharge head too high
Clogged inlet/impeller
Defective switch
Missing check valve
Clogged check valve in open
position
Float obstruction
TROUBLE:
Motor does not run.
Motor runs but no
water is delivered.
Pump does not
shut off.
Pump does not
deliver to full
capacity.
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE
POWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE
THE POWER FROM THE RECEPTACLE.
6