Data Sheet

Type 6012
9 | 14
Visit product website
5. Performancespecications
5.1. Power consumption
Standard version
Orice K
V
value
water
Pressure range Coil power Power consumption Response times
3.)
Circuit
function C
Circuit
function D
Inrush Hold Opening Closing
[mm] [m
3
/h]
1.)
[bar]
2.)
[bar]
2.)
[ms] [ms]
1.2 0.045 0…10 0…10 4WACor4WDC 9VA 6VA(4W) 7…10 9…12
1.6 0.06 0…6 0…6 4W 4W 7…12 7…12
1.)K
V
value:Flowratevalueforwater,measurementat+20°C,1bar
2.)
pressure at valve inlet and free outlet.
2.)Pressuredata:Overpressurewithrespecttoatmosphericpressure
3.)Responsetimes:Measuresat6bar
2.)
and+20°Catvalveoutletacc.toISO12238.Opening:pressurebuildup0to90%,closing:pressurerelief100to10%
Banjo version
Nennweite Q
Nn
-Wert
Luft
Druckbereich Spulenleistung Elektr. Leistung Schaltzeiten
3.)
Anzug Betrieb Önen Schließen
[mm] [l/min]
1.)
[bar]
2.)
[ms] [ms]
1.2 48 0…10 4WACoder4WDC 9VA 6VA(4W) 7…10 9…12
0…6 4W 4W 7…12 7…12
1.)Q
Nn
value:Flowratevalueforair,measuredat+20°C,6bar
2.)
pressureatvalveinletand1barpressuredierence
2.)Pressuredata:Overpressurewithrespecttoatmosphericpressure
3.)Responsetimes:Measuresat6bar
2.)
and+20°Catvalveoutletacc.toISO12238.Opening:pressurebuildup0to90%,closing:pressurerelief100to10%
6. Ordering information
6.1. Bürkert eShop – Easy ordering and quick delivery
Bürkert eShop – Easy ordering and fast delivery
YouwanttondyourdesiredBürkertproductorsparepartquicklyandorderdirectly?
Ouronlineshopisavailableforyou24/7.Signupandenjoyallthebenets.
Order online now
6.2. Bürkertproductlter
Bürkertproductlter–Getquicklytotherightproduct
You want to select products comfortably based on your technical requirements?
UsetheBürkertproductlterandndsuitablearticlesforyourapplicationquicklyand
easily.
Tryoutourproductlter