Instruction Manual

2
1 OPERATING INSTRUCTIONS
The operating instructions contain important information.
Read the operating instructions carefully and follow the safety instruc-
tions in particular, and also observe the operating conditions.
Operating instructions must be available to each user.
The liability and warranty for the device are void if the operating instruc-
tions are not followed.
1.1 Symbols
Designates an instruction to prevent risks.
designates a procedure which you must carry out.
Warning of injuries:
Danger!
Imminent danger! Serious or fatal injuries.
Warning!
Potential danger! Serious or fatal injuries.
Caution!
Danger! Minor or moderately severe injuries.
Warns of damage to property:
note!
2 INTENDED USE
Incorrect use of the solenoid valve Type 0287 can be dangerous
to people, nearby equipment and the environment.
The device is designed to control, shut off and meter neutral media up
to a viscosity of 21 mm
2
/s.
Provided the cable plug is connected and installed correctly, e.g. Bürk-
ert Type 2508, the device satisfies protection class IP65 in accordance
with DIN EN 60529 / IEC 60529.
Use according to the permitted data, operating conditions and con-
ditions of use specified in the contract documents and operating
instructions.
Correct transportation, correct storage and installation and careful use
and maintenance are essential for reliable and problem-free operation.
Use the device only as intended.
2.1 Definition of term
In these operating instructions, the term “device” always refers to the
solenoid valve Type 0287.
english
3
Risk of injury due to malfunction of valves with alternating
current (AC)!
Sticking core causes coil to overheat, resulting in a malfunction.
Monitor process to ensure function is in perfect working order!
Risk of short-circuit/escape of media through leaking screw joints!
Ensure seals are seated correctly.
Carefully screw valve and connection lines together.
General hazardous situations.
To prevent injury, ensure that:
Do not make any internal or external changes. Ensure that the system
cannot be activated unintentionally.
Installation and repair work may be carried out by authorized techni-
cians only and with the appropriate tools.
After an interruption in the power supply or pneumatic supply, ensure
that the process is restarted in a defined or controlled manner.
Do not put any loads on the body.
3 BASIC SAFETY INSTRUCTIONS
These safety instructions do not make allowance for any contingencies
and events which may arise during installation, operation and maintenance.
Danger – high pressure!
Before loosening the lines and valves, turn off the pressure and
vent the lines.
Risk of electric shock!
Before reaching into the system, switch off the power supply and
secure to prevent reactivation!
Observe applicable accident prevention and safety regulations for
electrical equipment!
Risk of burns/Risk of fire if used continuously through hot device
surface!
Keep the device away from highly flammable substances and media
and do not touch with bare hands.
english
4
The general rules of technology apply to application planning and
operation of the device.
The device may only be used in the explosion-protected area if an
appropriate additional identification is attached to the type label.
For use observe the additional information enclosed with the device
together with safety instructions for the explosion risk area.
3.1 Warranty
The warranty is only valid if the device is used as intended in accordance
with the specified application conditions.
3.2 Information on the internet
The operating instructions for type 0287 can be found on the internet at:
www.burkert.com
Type 0287
4 SYSTEM DESCRIPTION
4.1 General description
The solenoid valve modules
(SV modules) are stacked
in blocks with the aid of pull
rods and connection pieces.
The valve has the following
functions:
• Distributor (1 input, 2-10
outputs)
• Collector (1 output, 2-10
inputs)
• mixed (2-10 SV modules)
Collector
Collector
Distributor
Distributor
The SV modules with collector function have a non-return valve con-
nected upstream as standard. As a result, the minimum pressure
difference increases to 1 bar.
english
Type 0287